Place of Origin: | China Open Type Chiller |
Brand Name: | RS or OEM |
Certification: | CE for China water-cooled central water chillers manufacturer |
Model Number: | RS-L280WS |
Minimum Order Quantity: | 1 set of Open Type Chiller |
---|---|
Price: | contact us for water-cooled central water chiller price |
Packaging Details: | standard export packing of industry water-cooled central water chillers |
Delivery Time: | 15 days according to water-cooled central water chiller production |
Payment Terms: | T/T, West Union,MoneyGram,L/C etc |
Supply Ability: | 500 sets of water-cooled central water chillers according to China Manufacturer ability |
Product: | Open Type Chiller,China Water-cooled Water Chillers Manufacturer, China Water-cooled Central Water C | Keywords: | China Industrial Chillers OEM Factory; China Water Chillers OEM Plant; |
---|---|---|---|
Condition: | New Dual Screw Compressor Chiller | Warranty: | ONE Year For Dual Screw Compressor Chiller |
Item No.: RS-L280WS
RS-L280WS Dual Screw Compressor Water Chiller/ Industrial Water cooling machine/Water cooled chiller with best price
If you need the price of the dual screw compressor chiller, please do send an E-mail to: 15113320579@vip.126com
Description of the open type chillers,
The central water-cooled chillers adopt German made BITZER with twin screw compressors, models with one or two compressors, suitable for using R22.R407 and R134a refrigerants. High efficiency condenser and evaporator have manufactured under national "BR1” standard. Featuring stable heat exchange and ease of maintenance, advanced controller with built-in microprocessor which gives better performance than single chip based unit.
Features of the water cooled central water chillers,
Dual Screw Compressor Chiller/ OPEN TYPE CHILLERS
1. Industrial Chillers are widely used in many industries like plastic and rubber manufacturing, electronic productions, electroplating, medical chemistry, ultrasonic cooling and printing business etc. It could accurately provide needed temperature for modem industrial manufacturing and largely improve efficiency and product quality. Our Industrial Chillers are with simple operation. reasonable design and superior quality for more than one hundred different models, which are the best choice for modem industries.
2. Regarding to high power industrial chiller, screw type chiller is available.
3. Screw type chiller adopts screw compressor, high efficiency, low noise, durable service, reliable operation.
Specification of the water-cooled central water chillers,
Model | Unit | RS-L30WS | RS-L40WS | RS-L50WS | RS-L60WS | RS-L80WS | RS-L100WS | RS-L120WS | RS-L150WS | RS-L180WS | |
Refrigerating Capacity | KW | 88 | 118 | 152 | 172 | 230 | 292.8 | 343 | 492 | 530 | |
Kcal/h | 75680 | 101480 | 130720 | 147920 | 197800 | 251808 | 295152 | 423120 | 455800 | ||
Input Power | KW | 22 | 30 | 36 | 45 | 60 | 37.9x2 | 45x2 | 114 | 135 | |
Control Type | Expansion Valve | ||||||||||
Power | 3HP-380V/50HZ(200V/220V/415V 50HZ/60HZ) | ||||||||||
Evaporator | Type | Shell and Tube Type | |||||||||
Cooling water flow | m3/h | 19 | 21 | 26 | 30 | 39 | 55 | 68 | 86 | 96 | |
Water Page diameter | inch | 3" | 3" | 3" | 3" | 4" | 4" | 5" | 5" | 6" | |
Refrigerant Type | R22(R407C) | ||||||||||
Compressor | Type | Semi-Hermetic Screw | |||||||||
Quantity | 2001-2-4 | ||||||||||
Start up mode | Y-△ | ||||||||||
Capacity control | % | 0-25-50-75-100 | |||||||||
Condenser | Type | Shell and Tube Type | |||||||||
Cooling water flow | m3/h | 21 | 26 | 33 | 40 | 45 | 69 | 85 | 108 | 122 | |
Water page diameter | inch | 3" | 3" | 3" | 3" | 4" | 4" | 5" | 5" | 4"x2 | |
Safty Protection | High and low Pressure Protection,Over Load Protection,Over Temperature Protection,Phase Sequence Protection etc. | ||||||||||
Dimensions (L*W*H) | mm | 1980*750*1580 | 2350*750*1580 | 2550*750*1580 | 2550*785*1600 | 3600*765 *1650 | 3600*765 *1750 | 3850*765 *1750 | 3880*875 *1850 | 3910*875 *1950 | |
Unit Exchange | 1KW=860Kcal/h 1RT=3024Kcal/h 1Btu/hr=0.252Kcal/h |
Model | Unit | RS-L240WS | RS-L280WS | RS-L320WS | RS-L360WS | RS-L440WS | RS-L500WS | RS-L560WS | RS-L640WS | RS-L720WS | |
Refrigerating Capacity | KW | 792 | 872 | 980 | 1198 | 1380 | 1564 | 1768 | 1960 | 2396 | |
Kcal/h | 681120 | 749920 | 842800 | 1030280 | 1186800 | 1345040 | 1520480 | 1685600 | 2060560 | ||
Input Power | KW | 181 | 196 | 227 | 273 | 308 | 345 | 401 | 456 | 547 | |
Control Type | Expansion Valve | ||||||||||
Power | 3HP-380V/50HZ(200V/220V/415V 50HZ/60HZ) | ||||||||||
Evaporator | Type | Shell and Tube Type | |||||||||
Cooling water flow | m3/h | 136 | 150 | 168 | 206 | 240 | 273 | 308 | 337 | 412 | |
Water Page diameter | inch | 6" | 6" | 6" | 8" | 8" | 10" | 10" | 10" | 10" | |
Refrigerant Type | R22(R407C) | ||||||||||
Compressor | Type | Semi-Hermetic Screw | |||||||||
Quantity | 2001-2-4 | ||||||||||
Start up mode | Y-△ | ||||||||||
Capacity control | % | 0-25-50-75-100 | |||||||||
Condenser | Type | Shell and Tube Type | |||||||||
Cooling water flow | m3/h | 170 | 186 | 220 | 252 | 294 | 334 | 372 | 416 | 506 | |
Water page diameter | inch | 4"x2 | 5"x2 | 5"x2 | 6"x2 | 6"x2 | 6"x2 | 6"x2 | 8"x2 | 8"x2 | |
Safty Protection | High and low Pressure Protection,Over Load Protection,Over Temperature Protection,Phase Sequence Protection etc. | ||||||||||
Dimensions (L*W*H) | mm | 4150*1320 *2150 | 4250*1320 *2150 | 4350*1320 *2150 | 4450*1580 *2230 | 4900*1600 *2350 | 4950*1760 *2360 | 5010*1760 *2360 | 4310*2350 *2630 | 4310*2350 *2750 | |
Unit Exchange | 1KW=860Kcal/h 1RT=3024Kcal/h 1Btu/hr=0.252Kcal/h |
Note: 1.Cooling Capacity is calculated based on: inlet/outlet chilled fluid temperature: 12℃/7℃, inlet/outlet cooling water temperature: 30℃/35℃.
2.Working condition: Chilled fluid temperature from 5℃ to35℃, Inlet/outlet chilled fluid Temperature difference from 3℃ to 8℃.
Cooling water temperature: from 18℃to 37℃, Inlet/outlet cooling water Temperature difference: from 3.5℃ to 10℃.
We reserve the right to modify above information without prior notice.
Foundation and Installation of the water cooled central water chillers,
Selection of Installation Environment,
1) Please select a firm and solid ground which can fully support machine when running. The ground selection has also to avoid any happens of vibration and loudly environment.
2) The machine should be installed on a place without any exposures from wind, rain, sunlight, or any heat source occurrence.
3) Ambient temperature is from 0℃ to 40℃. Relative Humidity (RH) is within 75%.
4) The installation environment should be well ventilated and less dust.
When install, please preserve a maintenance space, as shown blow. For the cleaning of the condenser, please reserve space of 0.8L on the left or right side of the machine.
Foundation Base
1 )The foundation of the concrete base, according to the operation weight of the machines, will put on steel bars, diameter above 9.5 mm, and are clustered together on the upper and lower layer of the base, interspaced about 100mm.
5) When making concrete floor to be foundation. it is necessary to rough the surface. Clean the floor before the installation.
6) The concrete base has to be rigid; the mixing proportion of concrete is
1:2:4.Put required anchor bolts into base, according to the request. Polishing and flat the surface of the base when finished.
7) Put the machine on the base when it is fully dried out and rigid.
It has to be a well drainage works around the base to prevent water remaining.
Machine color--- blue or gray white and black, or others;
Machine brand--- factory brand, OEM brand or no brand;
We do OEM!
We do B2B, B2C!
RS Plastics Machinery Co.,LTD (Zhongshan·China) |
|||
Contact Person |
Mrs. Pearl Zhu |
Position |
Export Manager |
Mobile Phone |
0086-13590932590 |
|
263567704 |
Wechat APP |
zhhy18 |
Skype |
PEARL20128 |
E-mail-1 |
|||
E-mail-2 |
|||
Website |
If you need the price of the dual screw compressor chiller, please do send an E-mail to: 15113320579@vip.126com